Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Current limiting class3
Rated voltage230V
Frequency50 - 60Hz
Built-in depth70.5mm
Rated current3.5A
Release characteristicC
Over voltage category3
Rated insulation voltage Ui440V
Voltage typeAC
Additional equipment possibleYes
Pollution degree2
Degree of protection (IP)IP20
Width in number of modular spacings1
Number of protected poles1
Explosion-proofNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of poles (total)1
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Power loss1.3W
Connectable conductor cross section multi-wired1 - 25mm²
Concurrently switching neutral conductorNo
Flush-mounted installationNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C3,5/1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Current limiting class

3

Rated voltage

230V

Frequency

50 .. 60Hz

Built-in depth

70.5mm

Rated current

3.5A

Release characteristic

C

Over voltage category

3

Rated insulation voltage Ui

440V

Voltage type

AC

Additional equipment possible

Pollution degree

2

Degree of protection (IP)

IP20

Width in number of modular spacings

1

Number of protected poles

1

Explosion-proof

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of poles (total)

1

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Power loss

1.3W

Connectable conductor cross section multi-wired

1 .. 25mm²