Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current30A
Built-in depth70.5mm
Rated voltage250V
Voltage typeDC
Frequency50 - 60Hz
Release characteristicC
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 25mm²
Flush-mounted installationNo
Additional equipment possibleYes
Ambient temperature during operating-25 - 75°C
Power loss6W
Connectable conductor cross section multi-wired1 - 25mm²
Concurrently switching neutral conductorNo
Number of protected poles2
Width in number of modular spacings2
Rated impulse withstand voltage Uimp4kV
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Pollution degree2
Number of poles (total)2
Rated insulation voltage Ui440V
Explosion-proofNo
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C30/2-NA-DC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current

30A

Built-in depth

70.5mm

Rated voltage

250V

Voltage type

DC

Frequency

50 .. 60Hz

Release characteristic

C

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 25mm²

Flush-mounted installation

Additional equipment possible

Ambient temperature during operating

-25 .. 75°C

Power loss

6W

Connectable conductor cross section multi-wired

1 .. 25mm²

Concurrently switching neutral conductor

Number of protected poles

2

Width in number of modular spacings

2

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Pollution degree

2

Number of poles (total)

2

Rated insulation voltage Ui

440V

Explosion-proof

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA