  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Rated current6A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Number of protected poles2
Release characteristicC
Current limiting class3
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorNo
Pollution degree2
Voltage typeAC
Rated insulation voltage Ui440V
Width in number of modular spacings2
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Additional equipment possibleYes
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Power loss2.4W
Rated voltage415V
Frequency50 - 60Hz
Flush-mounted installationNo
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-25 - 75°C
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C6/2-NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Rated current

6A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Number of protected poles

2

Release characteristic

C

Current limiting class

3

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

Pollution degree

2

Voltage type

AC

Rated insulation voltage Ui

440V

Width in number of modular spacings

2

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Additional equipment possible

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Power loss

2.4W

Rated voltage

415V

Frequency

50 .. 60Hz

Flush-mounted installation

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Explosion-proof