Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Voltage typeAC
Connectable conductor cross section solid-core1 - 25mm²
Concurrently switching neutral conductorNo
Explosion-proofNo
Over voltage category3
Degree of protection (IP)IP20
Power loss2.4W
Number of protected poles2
Rated current6A
Pollution degree2
Rated insulation voltage Ui440V
Width in number of modular spacings2
Current limiting class3
Frequency50 - 60Hz
Release characteristicC
Rated voltage415V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Flush-mounted installationNo
Additional equipment possibleYes
Number of poles (total)2
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C6/2-RT

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Voltage type

AC

Connectable conductor cross section solid-core

1 .. 25mm²

Concurrently switching neutral conductor

Explosion-proof

Over voltage category

3

Degree of protection (IP)

IP20

Power loss

2.4W

Number of protected poles

2

Rated current

6A

Pollution degree

2

Rated insulation voltage Ui

440V

Width in number of modular spacings

2

Current limiting class

3

Frequency

50 .. 60Hz

Release characteristic

C

Rated voltage

415V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Flush-mounted installation

Additional equipment possible

Number of poles (total)

2

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.