Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Built-in depth70.5mm
Rated current6A
Frequency50 - 60Hz
Over voltage category3
Rated insulation voltage Ui440V
Current limiting class3
Release characteristicC
Rated voltage415V
Rated impulse withstand voltage Uimp4kV
Number of protected poles3
Width in number of modular spacings3
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Flush-mounted installationNo
Power loss3.6W
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Explosion-proofNo
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Additional equipment possibleYes
Pollution degree2
Number of poles (total)3
Connectable conductor cross section multi-wired1 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C6/3-NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Built-in depth

70.5mm

Rated current

6A

Frequency

50 .. 60Hz

Over voltage category

3

Rated insulation voltage Ui

440V

Current limiting class

3

Release characteristic

C

Rated voltage

415V

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

3

Width in number of modular spacings

3

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Flush-mounted installation

Power loss

3.6W

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Explosion-proof

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Additional equipment possible

Pollution degree

2

Number of poles (total)

3

Connectable conductor cross section multi-wired

1 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.