Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Rated voltage415V
Voltage typeAC
Release characteristicD
Rated current0.5A
Pollution degree2
Rated insulation voltage Ui440V
Current limiting class3
Over voltage category3
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Width in number of modular spacings2
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Number of protected poles2
Degree of protection (IP)IP20
Additional equipment possibleYes
Number of poles (total)2
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-D0,5/2-NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Rated voltage

415V

Voltage type

AC

Release characteristic

D

Rated current

0.5A

Pollution degree

2

Rated insulation voltage Ui

440V

Current limiting class

3

Over voltage category

3

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Number of protected poles

2

Degree of protection (IP)

IP20

Additional equipment possible

Number of poles (total)

2

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Explosion-proof

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.