Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Frequency50 - 60Hz
Current limiting class3
Release characteristicD
Rated voltage415V
Over voltage category3
Voltage typeAC
Built-in depth70.5mm
Rated current13A
Rated insulation voltage Ui440V
Pollution degree2
Width in number of modular spacings2
Explosion-proofNo
Power loss4W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section multi-wired1 - 25mm²
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Number of protected poles2
Flush-mounted installationNo
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp4kV
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-D13/2-NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Frequency

50 .. 60Hz

Current limiting class

3

Release characteristic

D

Rated voltage

415V

Over voltage category

3

Voltage type

AC

Built-in depth

70.5mm

Rated current

13A

Rated insulation voltage Ui

440V

Pollution degree

2

Width in number of modular spacings

2

Explosion-proof

Power loss

4W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Number of protected poles

2

Flush-mounted installation

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

4kV

Additional equipment possible