Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Rated current15A
Frequency50 - 60Hz
Built-in depth70.5mm
Release characteristicD
Rated voltage230V
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Over voltage category3
Explosion-proofNo
Current limiting class3
Power loss2.3W
Width in number of modular spacings2
Number of protected poles1
Rated insulation voltage Ui440V
Pollution degree2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section solid-core1 - 25mm²
Number of poles (total)2
Flush-mounted installationNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-D15/1N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Rated current

15A

Frequency

50 .. 60Hz

Built-in depth

70.5mm

Release characteristic

D

Rated voltage

230V

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Over voltage category

3

Explosion-proof

Current limiting class

3

Power loss

2.3W

Width in number of modular spacings

2

Number of protected poles

1

Rated insulation voltage Ui

440V

Pollution degree

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section solid-core

1 .. 25mm²

Number of poles (total)

2

Flush-mounted installation

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.