Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristicD
Number of poles (total)3
Rated current15A
Rated voltage415V
Number of protected poles3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Built-in depth70.5mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated insulation voltage Ui440V
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Power loss6W
Over voltage category3
Frequency50 - 60Hz
Rated impulse withstand voltage Uimp4kV
Current limiting class3
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Pollution degree2
Ambient temperature during operating-25 - 75°C
Width in number of modular spacings3
Connectable conductor cross section multi-wired1 - 25mm²
Additional equipment possibleYes
Connectable conductor cross section solid-core1 - 25mm²
Flush-mounted installationNo
Degree of protection (IP)IP20
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-D15/3-NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

D

Number of poles (total)

3

Rated current

15A

Rated voltage

415V

Number of protected poles

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Built-in depth

70.5mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated insulation voltage Ui

440V

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Power loss

6W

Over voltage category

3

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Pollution degree

2

Ambient temperature during operating

-25 .. 75°C

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

1 .. 25mm²

Additional equipment possible

Connectable conductor cross section solid-core

1 .. 25mm²

Flush-mounted installation

Degree of protection (IP)

IP20

Explosion-proof