Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Rated current16A
Frequency50 - 60Hz
Rated voltage240V
Built-in depth70.5mm
Release characteristicD
Rated insulation voltage Ui440V
Pollution degree2
Connectable conductor cross section solid-core1 - 25mm²
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Concurrently switching neutral conductorNo
Power loss2.3W
Rated impulse withstand voltage Uimp4kV
Explosion-proofNo
Current limiting class3
Number of poles (total)1
Number of protected poles1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Width in number of modular spacings1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Flush-mounted installationNo
Additional equipment possibleYes
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-D16/1-RT

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Rated current

16A

Frequency

50 .. 60Hz

Rated voltage

240V

Built-in depth

70.5mm

Release characteristic

D

Rated insulation voltage Ui

440V

Pollution degree

2

Connectable conductor cross section solid-core

1 .. 25mm²

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Concurrently switching neutral conductor

Power loss

2.3W

Rated impulse withstand voltage Uimp

4kV

Explosion-proof

Current limiting class

3

Number of poles (total)

1

Number of protected poles

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Width in number of modular spacings

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Flush-mounted installation

Additional equipment possible

Over voltage category

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.