Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated insulation voltage Ui440V
Rated current2A
Built-in depth70.5mm
Number of poles (total)2
Number of protected poles1
Power loss1.2W
Current limiting class3
Release characteristicD
Rated voltage230V
Width in number of modular spacings2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Connectable conductor cross section multi-wired1 - 25mm²
Voltage typeAC
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core1 - 25mm²
Explosion-proofNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Over voltage category3
Ambient temperature during operating-25 - 75°C
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Pollution degree2
Flush-mounted installationNo
Degree of protection (IP)IP20
Frequency50 - 60Hz
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-D2/1N

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated insulation voltage Ui

440V

Rated current

2A

Built-in depth

70.5mm

Number of poles (total)

2

Number of protected poles

1

Power loss

1.2W

Current limiting class

3

Release characteristic

D

Rated voltage

230V

Width in number of modular spacings

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Voltage type

AC

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1 .. 25mm²

Explosion-proof

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Over voltage category

3

Ambient temperature during operating

-25 .. 75°C

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Pollution degree

2

Flush-mounted installation

Degree of protection (IP)

IP20

Frequency

50 .. 60Hz