Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristicD
Rated insulation voltage Ui440V
Number of protected poles3
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp4kV
Built-in depth70.5mm
Current limiting class3
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated voltage415V
Rated current2A
Number of poles (total)3
Power loss3.3W
Concurrently switching neutral conductorNo
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Pollution degree2
Explosion-proofNo
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-25 - 75°C
Additional equipment possibleYes
Degree of protection (IP)IP20
Width in number of modular spacings3
Flush-mounted installationNo
Connectable conductor cross section multi-wired1 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-D2/3-RT

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

D

Rated insulation voltage Ui

440V

Number of protected poles

3

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

4kV

Built-in depth

70.5mm

Current limiting class

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated voltage

415V

Rated current

2A

Number of poles (total)

3

Power loss

3.3W

Concurrently switching neutral conductor

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Pollution degree

2

Explosion-proof

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Additional equipment possible

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.