Technical specifications

Width in number of modular spacings1
Pollution degree2
Built-in depth70.5mm
Current limiting class3
Explosion-proofNo
Frequency50 - 60Hz
Release characteristicD
Rated current25A
Rated insulation voltage Ui440V
Rated voltage240V
Voltage typeAC
Over voltage category3
Degree of protection (IP)IP20
Number of protected poles1
Power loss2.5W
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-25 - 75°C
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core1 - 25mm²
Number of poles (total)1
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-D25/1-RT

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Width in number of modular spacings

1

Pollution degree

2

Built-in depth

70.5mm

Current limiting class

3

Explosion-proof

Frequency

50 .. 60Hz

Release characteristic

D

Rated current

25A

Rated insulation voltage Ui

440V

Rated voltage

240V

Voltage type

AC

Over voltage category

3

Degree of protection (IP)

IP20

Number of protected poles

1

Power loss

2.5W

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Additional equipment possible

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1 .. 25mm²

Number of poles (total)

1

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

4kV