Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current40A
Built-in depth70.5mm
Rated impulse withstand voltage Uimp4kV
Number of protected poles3
Rated insulation voltage Ui440V
Voltage typeAC
Number of poles (total)3
Frequency50 - 60Hz
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Pollution degree2
Connectable conductor cross section multi-wired1 - 25mm²
Additional equipment possibleYes
Connectable conductor cross section solid-core1 - 25mm²
Release characteristicD
Rated voltage415V
Explosion-proofNo
Current limiting class3
Width in number of modular spacings3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Over voltage category3
Concurrently switching neutral conductorNo
Power loss9.3W
Ambient temperature during operating-25 - 75°C
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-D40/3-RT

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current

40A

Built-in depth

70.5mm

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

3

Rated insulation voltage Ui

440V

Voltage type

AC

Number of poles (total)

3

Frequency

50 .. 60Hz

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Pollution degree

2

Connectable conductor cross section multi-wired

1 .. 25mm²

Additional equipment possible

Connectable conductor cross section solid-core

1 .. 25mm²

Release characteristic

D

Rated voltage

415V

Explosion-proof

Current limiting class

3

Width in number of modular spacings

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Over voltage category

3

Concurrently switching neutral conductor

Power loss

9.3W

Ambient temperature during operating

-25 .. 75°C

Degree of protection (IP)

IP20

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.