Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristicD
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Built-in depth70.5mm
Rated impulse withstand voltage Uimp4kV
Rated voltage400V
Concurrently switching neutral conductorNo
Number of protected poles2
Power loss9.9W
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Pollution degree2
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 75°C
Current limiting class3
Additional equipment possibleYes
Width in number of modular spacings2
Voltage typeAC
Flush-mounted installationNo
Number of poles (total)2
Over voltage category3
Rated current50A
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Frequency50 - 60Hz
Explosion-proofNo
Connectable conductor cross section solid-core1 - 25mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-D50/2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Professional worker

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

D

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Built-in depth

70.5mm

Rated impulse withstand voltage Uimp

4kV

Rated voltage

400V

Concurrently switching neutral conductor

Number of protected poles

2

Power loss

9.9W

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Pollution degree

2

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 75°C

Current limiting class

3

Additional equipment possible

Width in number of modular spacings

2

Voltage type

AC

Flush-mounted installation

Number of poles (total)

2

Over voltage category

3

Rated current

50A

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Frequency

50 .. 60Hz

Explosion-proof

Connectable conductor cross section solid-core

1 .. 25mm²

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.