Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Pollution degree2
Explosion-proofNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Release characteristicD
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Over voltage category3
Additional equipment possibleYes
Number of poles (total)1
Number of protected poles1
Rated voltage240V
Degree of protection (IP)IP20
Rated current6A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Power loss1.2W
Width in number of modular spacings1
Built-in depth70.5mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Current limiting class3
Rated insulation voltage Ui440V
Connectable conductor cross section solid-core1 - 25mm²
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section multi-wired1 - 25mm²
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-D6/1-NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Pollution degree

2

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Release characteristic

D

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Over voltage category

3

Additional equipment possible

Number of poles (total)

1

Number of protected poles

1

Rated voltage

240V

Degree of protection (IP)

IP20

Rated current

6A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Power loss

1.2W

Width in number of modular spacings

1

Built-in depth

70.5mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Current limiting class

3

Rated insulation voltage Ui

440V

Connectable conductor cross section solid-core

1 .. 25mm²

Flush-mounted installation

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.