Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristicD
Width in number of modular spacings2
Over voltage category3
Degree of protection (IP)IP20
Rated current7A
Number of protected poles2
Pollution degree2
Rated voltage415V
Current limiting class3
Power loss2.8W
Explosion-proofNo
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Voltage typeAC
Built-in depth70.5mm
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-25 - 75°C
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Number of poles (total)2
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Additional equipment possibleYes
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-D7/2-NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

D

Width in number of modular spacings

2

Over voltage category

3

Degree of protection (IP)

IP20

Rated current

7A

Number of protected poles

2

Pollution degree

2

Rated voltage

415V

Current limiting class

3

Power loss

2.8W

Explosion-proof

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Voltage type

AC

Built-in depth

70.5mm

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Number of poles (total)

2

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Additional equipment possible

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.