Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of protected poles4
Built-in depth70.5mm
Release characteristicD
Rated current7A
Number of poles (total)4
Rated voltage415V
Flush-mounted installationNo
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Pollution degree2
Rated insulation voltage Ui440V
Additional equipment possibleYes
Frequency50 - 60Hz
Voltage typeAC
Width in number of modular spacings4
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-25 - 75°C
Explosion-proofNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Current limiting class3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-D7/4

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of protected poles

4

Built-in depth

70.5mm

Release characteristic

D

Rated current

7A

Number of poles (total)

4

Rated voltage

415V

Flush-mounted installation

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Pollution degree

2

Rated insulation voltage Ui

440V

Additional equipment possible

Frequency

50 .. 60Hz

Voltage type

AC

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Current limiting class

3

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.