Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Rated voltage415V
Built-in depth70.5mm
Rated current8A
Current limiting class3
Rated insulation voltage Ui440V
Explosion-proofNo
Frequency50 - 60Hz
Width in number of modular spacings2
Over voltage category3
Release characteristicD
Pollution degree2
Power loss2.6W
Concurrently switching neutral conductorNo
Number of protected poles2
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Flush-mounted installationNo
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Additional equipment possibleYes
Connectable conductor cross section solid-core1 - 25mm²
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-D8/2-RT

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Rated voltage

415V

Built-in depth

70.5mm

Rated current

8A

Current limiting class

3

Rated insulation voltage Ui

440V

Explosion-proof

Frequency

50 .. 60Hz

Width in number of modular spacings

2

Over voltage category

3

Release characteristic

D

Pollution degree

2

Power loss

2.6W

Concurrently switching neutral conductor

Number of protected poles

2

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Flush-mounted installation

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Additional equipment possible

Connectable conductor cross section solid-core

1 .. 25mm²

Rated impulse withstand voltage Uimp

4kV