Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Rated voltage400V
Frequency50 - 60Hz
Current limiting class3
Built-in depth70.5mm
Width in number of modular spacings4
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Pollution degree2
Rated insulation voltage Ui440V
Release characteristicK
Number of protected poles3
Over voltage category3
Rated current8A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Suitable for flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Number of poles (total)4
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-K8/3N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Rated voltage

400V

Frequency

50 .. 60Hz

Current limiting class

3

Built-in depth

70.5mm

Width in number of modular spacings

4

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Pollution degree

2

Rated insulation voltage Ui

440V

Release characteristic

K

Number of protected poles

3

Over voltage category

3

Rated current

8A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Suitable for flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

4

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Related products