Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Rated voltage230V
Built-in depth70.5mm
Rated current13A
Degree of protection (IP)IP20
Number of protected poles1
Current limiting class3
Width in number of modular spacings2
Pollution degree2
Over voltage category3
Release characteristicB
Rated insulation voltage Ui440V
Connectable conductor cross section multi-wired1 - 25mm²
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Ambient temperature during operating-25 - 75°C
Additional equipment possibleYes
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated impulse withstand voltage Uimp4kV
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZT-B13/1N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Rated voltage

230V

Built-in depth

70.5mm

Rated current

13A

Degree of protection (IP)

IP20

Number of protected poles

1

Current limiting class

3

Width in number of modular spacings

2

Pollution degree

2

Over voltage category

3

Release characteristic

B

Rated insulation voltage Ui

440V

Connectable conductor cross section multi-wired

1 .. 25mm²

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Ambient temperature during operating

-25 .. 75°C

Additional equipment possible

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated impulse withstand voltage Uimp

4kV

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.