Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristicB
Built-in depth70.5mm
Rated current15A
Rated voltage240V
Number of poles (total)1
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Number of protected poles1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated impulse withstand voltage Uimp4kV
Power loss2.1W
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Pollution degree2
Voltage typeAC
Concurrently switching neutral conductorNo
Width in number of modular spacings1
Degree of protection (IP)IP20
Over voltage category3
Additional equipment possibleYes
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Current limiting class3
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section solid-core1 - 25mm²
Explosion-proofNo
Connectable conductor cross section multi-wired1 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZT-B15/1

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

B

Built-in depth

70.5mm

Rated current

15A

Rated voltage

240V

Number of poles (total)

1

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated impulse withstand voltage Uimp

4kV

Power loss

2.1W

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Pollution degree

2

Voltage type

AC

Concurrently switching neutral conductor

Width in number of modular spacings

1

Degree of protection (IP)

IP20

Over voltage category

3

Additional equipment possible

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Current limiting class

3

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section solid-core

1 .. 25mm²

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.