  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Built-in depth70.5mm
Release characteristicB
Rated voltage240V
Frequency50 - 60Hz
Rated current32A
Rated insulation voltage Ui440V
Explosion-proofNo
Over voltage category3
Current limiting class3
Pollution degree2
Width in number of modular spacings1
Number of protected poles1
Degree of protection (IP)IP20
Number of poles (total)1
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Flush-mounted installationNo
Connectable conductor cross section multi-wired1 - 25mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Power loss3.7W
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-25 - 75°C
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZT-B32/1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Built-in depth

70.5mm

Release characteristic

B

Rated voltage

240V

Frequency

50 .. 60Hz

Rated current

32A

Rated insulation voltage Ui

440V

Explosion-proof

Over voltage category

3

Current limiting class

3

Pollution degree

2

Width in number of modular spacings

1

Number of protected poles

1

Degree of protection (IP)

IP20

Number of poles (total)

1

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 25mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Power loss

3.7W

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA