Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)3
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Built-in depth70.5mm
Number of protected poles3
Release characteristicC
Flush-mounted installationNo
Power loss6.5W
Rated current12A
Rated voltage230V
Frequency50 - 60Hz
Additional equipment possibleYes
Current limiting class3
Voltage typeAC
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Pollution degree2
Degree of protection (IP)IP20
Width in number of modular spacings3
Over voltage category3
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Explosion-proofNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated insulation voltage Ui440V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZT-C12/3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Professional worker

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)

3

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Built-in depth

70.5mm

Number of protected poles

3

Release characteristic

C

Flush-mounted installation

Power loss

6.5W

Rated current

12A

Rated voltage

230V

Frequency

50 .. 60Hz

Additional equipment possible

Current limiting class

3

Voltage type

AC

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Pollution degree

2

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Over voltage category

3

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated insulation voltage Ui

440V