Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Rated voltage230V
Rated current13A
Voltage typeAC
Frequency50 - 60Hz
Pollution degree2
Release characteristicC
Explosion-proofNo
Ambient temperature during operating-25 - 75°C
Number of protected poles2
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Rated impulse withstand voltage Uimp4kV
Width in number of modular spacings2
Additional equipment possibleYes
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Flush-mounted installationNo
Current limiting class3
Connectable conductor cross section solid-core1 - 25mm²
Rated insulation voltage Ui440V
Over voltage category3
Power loss5.3W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZT-C13/2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Rated voltage

230V

Rated current

13A

Voltage type

AC

Frequency

50 .. 60Hz

Pollution degree

2

Release characteristic

C

Explosion-proof

Ambient temperature during operating

-25 .. 75°C

Number of protected poles

2

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

4kV

Width in number of modular spacings

2

Additional equipment possible

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Flush-mounted installation

Current limiting class

3

Connectable conductor cross section solid-core

1 .. 25mm²

Rated insulation voltage Ui

440V

Over voltage category

3

Power loss

5.3W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA