Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristicC
Number of protected poles2
Voltage typeAC
Width in number of modular spacings2
Pollution degree2
Rated voltage230V
Explosion-proofNo
Rated insulation voltage Ui440V
Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Built-in depth70.5mm
Degree of protection (IP)IP20
Power loss4.4W
Rated current15A
Current limiting class3
Over voltage category3
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated impulse withstand voltage Uimp4kV
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZT-C15/2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

C

Number of protected poles

2

Voltage type

AC

Width in number of modular spacings

2

Pollution degree

2

Rated voltage

230V

Explosion-proof

Rated insulation voltage Ui

440V

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Built-in depth

70.5mm

Degree of protection (IP)

IP20

Power loss

4.4W

Rated current

15A

Current limiting class

3

Over voltage category

3

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated impulse withstand voltage Uimp

4kV

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.