Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)IP20
Voltage typeAC
Suitable for flush-mounted installationNo
Built-in depth70.5mm
Rated voltage230V
Rated current4A
Width in number of modular spacings2
Release characteristicD
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Number of protected poles1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Over voltage category3
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Number of poles (total)2
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Additional equipment possibleYes
Frequency50 - 60Hz
Pollution degree2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZT-D4/1N

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Built-in depth

70.5mm

Rated voltage

230V

Rated current

4A

Width in number of modular spacings

2

Release characteristic

D

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Number of protected poles

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Over voltage category

3

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Number of poles (total)

2

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Additional equipment possible

Frequency

50 .. 60Hz

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.