Technical specifications

Release characteristicD
Number of poles (total)4
Number of protected poles4
Built-in depth70.5mm
Rated impulse withstand voltage Uimp4kV
Rated voltage230V
Rated current4A
Rated insulation voltage Ui440V
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Power loss5.9W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Concurrently switching neutral conductorYes
Flush-mounted installationNo
Additional equipment possibleYes
Pollution degree2
Current limiting class3
Width in number of modular spacings4
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-25 - 75°C
Explosion-proofNo
Connectable conductor cross section solid-core1 - 25mm²
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZT-D4/4

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

D

Number of poles (total)

4

Number of protected poles

4

Built-in depth

70.5mm

Rated impulse withstand voltage Uimp

4kV

Rated voltage

230V

Rated current

4A

Rated insulation voltage Ui

440V

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Power loss

5.9W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Concurrently switching neutral conductor

Flush-mounted installation

Additional equipment possible

Pollution degree

2

Current limiting class

3

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Explosion-proof

Connectable conductor cross section solid-core

1 .. 25mm²

Over voltage category

3