Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current40A
Frequency50 - 60Hz
Over voltage category3
Built-in depth70.5mm
Rated voltage230V
Rated insulation voltage Ui440V
Release characteristicD
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Number of poles (total)4
Width in number of modular spacings4
Additional equipment possibleYes
Degree of protection (IP)IP20
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Pollution degree2
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wired1 - 25mm²
Number of protected poles3
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section solid-core1 - 25mm²
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZT-D40/3N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current

40A

Frequency

50 .. 60Hz

Over voltage category

3

Built-in depth

70.5mm

Rated voltage

230V

Rated insulation voltage Ui

440V

Release characteristic

D

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Number of poles (total)

4

Width in number of modular spacings

4

Additional equipment possible

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Pollution degree

2

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

1 .. 25mm²

Number of protected poles

3

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section solid-core

1 .. 25mm²

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.