Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current1A
Built-in depth70.5mm
Number of protected poles2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Release characteristicZ
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Number of poles (total)2
Rated voltage400V
Voltage typeAC
Current limiting class3
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Flush-mounted installationNo
Power loss7.1W
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Over voltage category3
Width in number of modular spacings2
Pollution degree2
Additional equipment possibleYes
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section solid-core1 - 25mm²
Explosion-proofNo
Connectable conductor cross section multi-wired1 - 25mm²
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-Z1/2

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current

1A

Built-in depth

70.5mm

Number of protected poles

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Release characteristic

Z

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Number of poles (total)

2

Rated voltage

400V

Voltage type

AC

Current limiting class

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Flush-mounted installation

Power loss

7.1W

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Over voltage category

3

Width in number of modular spacings

2

Pollution degree

2

Additional equipment possible

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section solid-core

1 .. 25mm²

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 25mm²

Degree of protection (IP)

IP20

Related products