Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristicC
Frequency50 - 60Hz
Built-in depth70.5mm
Current limiting class3
Rated voltage400V
Rated insulation voltage Ui440V
Rated current13A
Voltage typeAC
Pollution degree2
Power loss11W
Explosion-proofNo
Degree of protection (IP)IP20
Over voltage category3
Width in number of modular spacings3
Concurrently switching neutral conductorNo
Number of protected poles4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Ambient temperature during operating-25 - 75°C
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-Z13/4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

C

Frequency

50 .. 60Hz

Built-in depth

70.5mm

Current limiting class

3

Rated voltage

400V

Rated insulation voltage Ui

440V

Rated current

13A

Voltage type

AC

Pollution degree

2

Power loss

11W

Explosion-proof

Degree of protection (IP)

IP20

Over voltage category

3

Width in number of modular spacings

3

Concurrently switching neutral conductor

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Ambient temperature during operating

-25 .. 75°C

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation