Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristicZ
Built-in depth70.5mm
Rated current25A
Rated insulation voltage Ui440V
Rated voltage400V
Number of poles (total)4
Voltage typeAC
Number of protected poles4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Concurrently switching neutral conductorYes
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Power loss11.4W
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Flush-mounted installationNo
Pollution degree2
Connectable conductor cross section solid-core1 - 25mm²
Over voltage category3
Explosion-proofNo
Rated impulse withstand voltage Uimp4kV
Width in number of modular spacings4
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Connectable conductor cross section multi-wired1 - 25mm²
Frequency50 - 60Hz
Ambient temperature during operating-25 - 75°C

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-Z25/4

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

Z

Built-in depth

70.5mm

Rated current

25A

Rated insulation voltage Ui

440V

Rated voltage

400V

Number of poles (total)

4

Voltage type

AC

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Concurrently switching neutral conductor

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Power loss

11.4W

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Flush-mounted installation

Pollution degree

2

Connectable conductor cross section solid-core

1 .. 25mm²

Over voltage category

3

Explosion-proof

Rated impulse withstand voltage Uimp

4kV

Width in number of modular spacings

4

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Frequency

50 .. 60Hz

Ambient temperature during operating

-25 .. 75°C

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.