Voltage typeAC
Built-in depth70.5mm
Rated current8A
Frequency50 - 60Hz
Rated voltage400V
Rated insulation voltage Ui440V
Power loss10W
Degree of protection (IP)IP20
Over voltage category3
Concurrently switching neutral conductorNo
Release characteristicZ
Current limiting class3
Width in number of modular spacings3
Pollution degree2
Number of protected poles3
Explosion-proofNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Ambient temperature during operating-25 - 75°C
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Number of poles (total)3
Flush-mounted installationNo
Additional equipment possibleYes
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-Z8/3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Built-in depth

70.5mm

Rated current

8A

Frequency

50 .. 60Hz

Rated voltage

400V

Rated insulation voltage Ui

440V

Power loss

10W

Degree of protection (IP)

IP20

Over voltage category

3

Concurrently switching neutral conductor

Release characteristic

Z

Current limiting class

3

Width in number of modular spacings

3

Pollution degree

2

Number of protected poles

3

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Ambient temperature during operating

-25 .. 75°C

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Number of poles (total)

3

Flush-mounted installation

Additional equipment possible

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA