Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Surge current capacity3kA
Width in number of modular spacings2
Built-in depth70mm
Voltage typeAC
Current limiting class3
Over voltage category3
Rated current13A
Rated voltage240V
Rated insulation voltage Ui250V
Leakage current typeA
Pollution degree2
Rated fault current0.03A
Release characteristicB
Frequency50 Hz
Degree of protection (IP)IP20
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorNo
Anti-nuisance tripping versionYes
Number of protected poles2
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity according to IEC 60947-20kA
Disconnection characteristicShort-time delayed
With interlocking deviceNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated short-circuit breaking capacity according to EN 6100910kA
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired1 - 25mm²
Number of poles (total)2
Connectable conductor cross section solid-core1 - 25mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBdM-B13/2/003-G/A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Surge current capacity

3kA

Width in number of modular spacings

2

Built-in depth

70mm

Voltage type

AC

Current limiting class

3

Over voltage category

3

Rated current

13A

Rated voltage

240V

Rated insulation voltage Ui

250V

Leakage current type

A

Pollution degree

2

Rated fault current

0.03A

Release characteristic

B

Frequency

50 Hz

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Anti-nuisance tripping version

Number of protected poles

2

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Disconnection characteristic

Short-time delayed

With interlocking device

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

1 .. 25mm²

Number of poles (total)

2

Connectable conductor cross section solid-core

1 .. 25mm²

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.