Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Release characteristicC
Rated insulation voltage Ui250V
Surge current capacity3kA
Degree of protection (IP)IP20
Pollution degree2
Frequency50 Hz
Width in number of modular spacings2
Built-in depth70mm
Current limiting class3
Rated voltage240V
Over voltage category3
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity according to IEC 60947-20kA
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired1 - 25mm²
Number of protected poles2
Rated short-circuit breaking capacity according to EN 6100910kA
Disconnection characteristicShort-time delayed
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Ambient temperature during operating-25 - 40°C
Rated impulse withstand voltage Uimp4kV
With interlocking deviceNo
Anti-nuisance tripping versionYes
Rated current16A
Rated fault current0.1A
Leakage current typeA
Number of poles (total)2

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBdM-C16/2/01-G/A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Release characteristic

C

Rated insulation voltage Ui

250V

Surge current capacity

3kA

Degree of protection (IP)

IP20

Pollution degree

2

Frequency

50 Hz

Width in number of modular spacings

2

Built-in depth

70mm

Current limiting class

3

Rated voltage

240V

Over voltage category

3

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

1 .. 25mm²

Number of protected poles

2

Rated short-circuit breaking capacity according to EN 61009

10kA

Disconnection characteristic

Short-time delayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Ambient temperature during operating

-25 .. 40°C

Rated impulse withstand voltage Uimp

4kV

With interlocking device

Anti-nuisance tripping version

Rated current

16A

Rated fault current

0.1A

Leakage current type

A

Number of poles (total)

2

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.