Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Release characteristicC
Voltage typeAC
Rated voltage240V
Built-in depth70mm
Current limiting class3
Rated insulation voltage Ui250V
Width in number of modular spacings2
Frequency50 Hz
Over voltage category3
Degree of protection (IP)IP20
Pollution degree2
Surge current capacity3kA
Number of protected poles1
Rated short-circuit breaking capacity according to IEC 60947-20kA
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core1 - 25mm²
Suitable for flush-mounted installationNo
With interlocking deviceNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Anti-nuisance tripping versionYes
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-25 - 40°C
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 6100910kA
Disconnection characteristicShort-time delayed
Rated current20A
Rated fault current0.03A
Leakage current typeA
Number of poles (total)2

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBdM-C20/1N/003-G/A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

C

Voltage type

AC

Rated voltage

240V

Built-in depth

70mm

Current limiting class

3

Rated insulation voltage Ui

250V

Width in number of modular spacings

2

Frequency

50 Hz

Over voltage category

3

Degree of protection (IP)

IP20

Pollution degree

2

Surge current capacity

3kA

Number of protected poles

1

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1 .. 25mm²

Suitable for flush-mounted installation

With interlocking device

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 40°C

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

10kA

Disconnection characteristic

Short-time delayed

Rated current

20A

Rated fault current

0.03A

Leakage current type

A

Number of poles (total)

2