Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70mm
Voltage typeAC
Rated voltage240V
Surge current capacity3kA
Width in number of modular spacings2
Current limiting class3
Pollution degree2
Degree of protection (IP)IP20
Rated insulation voltage Ui250V
Over voltage category3
Frequency50 Hz
Number of protected poles1
Concurrently switching neutral conductorYes
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity according to IEC 60947-20kA
Rated short-circuit breaking capacity according to EN 6100910kA
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section multi-wired1 - 25mm²
With interlocking deviceNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated impulse withstand voltage Uimp4kV
Anti-nuisance tripping versionYes
Disconnection characteristicShort-time delayed
Release characteristicC
Connectable conductor cross section solid-core1 - 25mm²
Rated current20A
Rated fault current0.1A
Leakage current typeA
Number of poles (total)2

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBdM-C20/1N/01-G/A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70mm

Voltage type

AC

Rated voltage

240V

Surge current capacity

3kA

Width in number of modular spacings

2

Current limiting class

3

Pollution degree

2

Degree of protection (IP)

IP20

Rated insulation voltage Ui

250V

Over voltage category

3

Frequency

50 Hz

Number of protected poles

1

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section multi-wired

1 .. 25mm²

With interlocking device

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

Disconnection characteristic

Short-time delayed

Release characteristic

C

Connectable conductor cross section solid-core

1 .. 25mm²

Rated current

20A

Rated fault current

0.1A

Leakage current type

A

Number of poles (total)

2

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.