Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Current limiting class3
Rated current10A
Surge current capacity3kA
Concurrently switching neutral conductorYes
Frequency50 Hz
Pollution degree2
Rated fault current0.1A
Over voltage category3
Built-in depth70mm
Release characteristicD
Degree of protection (IP)IP20
Number of protected poles1
Voltage typeAC
Width in number of modular spacings2
Rated short-circuit breaking capacity according to IEC 60947-20kA
Leakage current typeA
Rated insulation voltage Ui250V
Rated voltage240V
Connectable conductor cross section multi-wired1 - 25mm²
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core1 - 25mm²
Number of poles (total)2
Disconnection characteristicShort-time delayed
Anti-nuisance tripping versionYes
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
With interlocking deviceNo
Rated short-circuit breaking capacity according to EN 6100910kA
Ambient temperature during operating-25 - 40°C

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBdM-D10/1N/01-G/A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Current limiting class

3

Rated current

10A

Surge current capacity

3kA

Concurrently switching neutral conductor

Frequency

50 Hz

Pollution degree

2

Rated fault current

0.1A

Over voltage category

3

Built-in depth

70mm

Release characteristic

D

Degree of protection (IP)

IP20

Number of protected poles

1

Voltage type

AC

Width in number of modular spacings

2

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Leakage current type

A

Rated insulation voltage Ui

250V

Rated voltage

240V

Connectable conductor cross section multi-wired

1 .. 25mm²

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

1 .. 25mm²

Number of poles (total)

2

Disconnection characteristic

Short-time delayed

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

With interlocking device

Rated short-circuit breaking capacity according to EN 61009

10kA

Ambient temperature during operating

-25 .. 40°C

Related products