Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated insulation voltage Ui250V
Release characteristicD
Voltage typeAC
Surge current capacity3kA
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Rated current13A
Rated voltage240V
Current limiting class3
Rated fault current0.03A
Degree of protection (IP)IP20
Leakage current typeA
Frequency50 Hz
Number of protected poles1
Built-in depth70mm
Width in number of modular spacings2
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity according to IEC 60947-20kA
Concurrently switching neutral conductorYes
Pollution degree2
Over voltage category3
Ambient temperature during operating-25 - 40°C
With interlocking deviceNo
Anti-nuisance tripping versionYes
Disconnection characteristicShort-time delayed
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated short-circuit breaking capacity according to EN 6100910kA
Rated impulse withstand voltage Uimp4kV

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBdM-D13/1N/003-G/A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated insulation voltage Ui

250V

Release characteristic

D

Voltage type

AC

Surge current capacity

3kA

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated current

13A

Rated voltage

240V

Current limiting class

3

Rated fault current

0.03A

Degree of protection (IP)

IP20

Leakage current type

A

Frequency

50 Hz

Number of protected poles

1

Built-in depth

70mm

Width in number of modular spacings

2

Suitable for flush-mounted installation

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Concurrently switching neutral conductor

Pollution degree

2

Over voltage category

3

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Anti-nuisance tripping version

Disconnection characteristic

Short-time delayed

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated impulse withstand voltage Uimp

4kV

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.