Technical specifications

Built-in depth70mm
Rated voltage240V
Leakage current typeA
Rated fault current0.1A
Release characteristicD
Rated insulation voltage Ui250V
Rated current6A
Current limiting class3
Surge current capacity3kA
Voltage typeAC
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Pollution degree2
Disconnection characteristicShort-time delayed
Rated short-circuit breaking capacity according to IEC 60947-20kA
With interlocking deviceNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Number of poles (total)2
Ambient temperature during operating-25 - 40°C
Anti-nuisance tripping versionYes
Rated short-circuit breaking capacity according to EN 6100910kA
Width in number of modular spacings2
Connectable conductor cross section solid-core1 - 25mm²
Number of protected poles2
Rated impulse withstand voltage Uimp4kV
Over voltage category3
Frequency50 Hz
Suitable for flush-mounted installationNo
Connectable conductor cross section multi-wired1 - 25mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBdM-D6/2/01-G/A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70mm

Rated voltage

240V

Leakage current type

A

Rated fault current

0.1A

Release characteristic

D

Rated insulation voltage Ui

250V

Rated current

6A

Current limiting class

3

Surge current capacity

3kA

Voltage type

AC

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Pollution degree

2

Disconnection characteristic

Short-time delayed

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

With interlocking device

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Number of poles (total)

2

Ambient temperature during operating

-25 .. 40°C

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

10kA

Width in number of modular spacings

2

Connectable conductor cross section solid-core

1 .. 25mm²

Number of protected poles

2

Rated impulse withstand voltage Uimp

4kV

Over voltage category

3

Frequency

50 Hz

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 25mm²

Related products