Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated current10A
Voltage typeAC
Release characteristicB
Built-in depth75.5mm
Number of protected poles2
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity according to IEC 60947-20kA
Connectable conductor cross section multi-wired1 - 25mm²
Over voltage category3
Degree of protection (IP)IP20
Suitable for flush-mounted installationNo
Leakage current typeA
Width in number of modular spacings2
Current limiting class3
Concurrently switching neutral conductorNo
Frequency50 Hz
Pollution degree2
Rated fault current0.03A
Rated voltage240V
Connectable conductor cross section solid-core1 - 25mm²
Surge current capacity0.25kA
With interlocking deviceNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Ambient temperature during operating-25 - 40°C
Number of poles (total)2
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicShort-time delayed
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-B10/2/003-LIA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated current

10A

Voltage type

AC

Release characteristic

B

Built-in depth

75.5mm

Number of protected poles

2

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Over voltage category

3

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Leakage current type

A

Width in number of modular spacings

2

Current limiting class

3

Concurrently switching neutral conductor

Frequency

50 Hz

Pollution degree

2

Rated fault current

0.03A

Rated voltage

240V

Connectable conductor cross section solid-core

1 .. 25mm²

Surge current capacity

0.25kA

With interlocking device

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Ambient temperature during operating

-25 .. 40°C

Number of poles (total)

2

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Short-time delayed

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.