Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated current13A
Voltage typeAC
Built-in depth75.5mm
Number of protected poles1
Rated fault current0.3A
Frequency50 Hz
Rated insulation voltage Ui500V
Anti-nuisance tripping versionNo
Current limiting class3
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 40°C
Release characteristicB
Width in number of modular spacings2
Concurrently switching neutral conductorYes
Surge current capacity0.25kA
Connectable conductor cross section multi-wired1 - 25mm²
With interlocking deviceNo
Connectable conductor cross section solid-core1 - 25mm²
Flush-mounted installationNo
Over voltage category3
Number of poles (total)2
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to IEC 60947-20kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated voltage240V
Degree of protection (IP)IP20
Leakage current typeAC
Pollution degree2
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-B13/1N/03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated current

13A

Voltage type

AC

Built-in depth

75.5mm

Number of protected poles

1

Rated fault current

0.3A

Frequency

50 Hz

Rated insulation voltage Ui

500V

Anti-nuisance tripping version

Current limiting class

3

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 40°C

Release characteristic

B

Width in number of modular spacings

2

Concurrently switching neutral conductor

Surge current capacity

0.25kA

Connectable conductor cross section multi-wired

1 .. 25mm²

With interlocking device

Connectable conductor cross section solid-core

1 .. 25mm²

Flush-mounted installation

Over voltage category

3

Number of poles (total)

2

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated voltage

240V

Degree of protection (IP)

IP20

Leakage current type

AC

Pollution degree

2

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.