Technical specifications

Built-in depth75.5mm
Rated current13A
Rated insulation voltage Ui500V
Rated fault current0.3A
Rated voltage415V
Voltage typeAC
Over voltage category3
Surge current capacity0.25kA
Pollution degree2
Degree of protection (IP)IP20
Current limiting class3
Leakage current typeA
Release characteristicB
Frequency50 Hz
Width in number of modular spacings4
Number of protected poles4
Rated short-circuit breaking capacity according to IEC 60947-20kA
Number of poles (total)4
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wired1 - 25mm²
Anti-nuisance tripping versionNo
Flush-mounted installationNo
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-25 - 40°C
With interlocking deviceNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-B13/3N/03-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

75.5mm

Rated current

13A

Rated insulation voltage Ui

500V

Rated fault current

0.3A

Rated voltage

415V

Voltage type

AC

Over voltage category

3

Surge current capacity

0.25kA

Pollution degree

2

Degree of protection (IP)

IP20

Current limiting class

3

Leakage current type

A

Release characteristic

B

Frequency

50 Hz

Width in number of modular spacings

4

Number of protected poles

4

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Number of poles (total)

4

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

1 .. 25mm²

Anti-nuisance tripping version

Flush-mounted installation

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated impulse withstand voltage Uimp

4kV