Technical specifications

Built-in depth75.5mm
Voltage typeAC
Rated current16A
Width in number of modular spacings2
Current limiting class3
Connectable conductor cross section solid-core1 - 25mm²
With interlocking deviceNo
Rated short-circuit breaking capacity according to IEC 60947-20kA
Number of protected poles1
Connectable conductor cross section multi-wired1 - 25mm²
Degree of protection (IP)IP20
Frequency50 Hz
Concurrently switching neutral conductorYes
Leakage current typeA
Rated fault current0.01A
Rated voltage240V
Pollution degree2
Release characteristicB
Over voltage category3
Rated insulation voltage Ui500V
Surge current capacity0.25kA
Disconnection characteristicUndelayed
Ambient temperature during operating-25 - 40°C
Flush-mounted installationNo
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-B16/1N/001-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

75.5mm

Voltage type

AC

Rated current

16A

Width in number of modular spacings

2

Current limiting class

3

Connectable conductor cross section solid-core

1 .. 25mm²

With interlocking device

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Number of protected poles

1

Connectable conductor cross section multi-wired

1 .. 25mm²

Degree of protection (IP)

IP20

Frequency

50 Hz

Concurrently switching neutral conductor

Leakage current type

A

Rated fault current

0.01A

Rated voltage

240V

Pollution degree

2

Release characteristic

B

Over voltage category

3

Rated insulation voltage Ui

500V

Surge current capacity

0.25kA

Disconnection characteristic

Undelayed

Ambient temperature during operating

-25 .. 40°C

Flush-mounted installation

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.