Technical specifications

Release characteristicB
Width in number of modular spacings2
Voltage typeAC
Number of protected poles1
Frequency50 Hz
Degree of protection (IP)IP20
Over voltage category3
Rated voltage240V
With interlocking deviceNo
Rated current2A
Pollution degree2
Built-in depth75.5mm
Connectable conductor cross section solid-core1 - 25mm²
Leakage current typeA
Connectable conductor cross section multi-wired1 - 25mm²
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to IEC 60947-20kA
Surge current capacity0.25kA
Ambient temperature during operating-25 - 40°C
Current limiting class3
Rated fault current0.03A
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
Number of poles (total)2
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-B2/1N/003-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

B

Width in number of modular spacings

2

Voltage type

AC

Number of protected poles

1

Frequency

50 Hz

Degree of protection (IP)

IP20

Over voltage category

3

Rated voltage

240V

With interlocking device

Rated current

2A

Pollution degree

2

Built-in depth

75.5mm

Connectable conductor cross section solid-core

1 .. 25mm²

Leakage current type

A

Connectable conductor cross section multi-wired

1 .. 25mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Surge current capacity

0.25kA

Ambient temperature during operating

-25 .. 40°C

Current limiting class

3

Rated fault current

0.03A

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Number of poles (total)

2

Anti-nuisance tripping version