Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Release characteristicB
Rated insulation voltage Ui500V
Built-in depth75.5mm
Voltage typeAC
Rated voltage240V
Current limiting class3
Surge current capacity3kA
Over voltage category3
Degree of protection (IP)IP20
Number of protected poles1
Concurrently switching neutral conductorYes
Width in number of modular spacings2
Suitable for flush-mounted installationNo
Pollution degree2
Rated short-circuit breaking capacity according to IEC 60947-26kA
With interlocking deviceNo
Frequency50 Hz
Disconnection characteristicShort-time delayed
Anti-nuisance tripping versionYes
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-25 - 40°C
Rated short-circuit breaking capacity according to EN 610096kA
Connectable conductor cross section solid-core1 - 25mm²
Rated current40A
Rated fault current0.03A
Leakage current typeA
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-B40/1N/003-G/A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

B

Rated insulation voltage Ui

500V

Built-in depth

75.5mm

Voltage type

AC

Rated voltage

240V

Current limiting class

3

Surge current capacity

3kA

Over voltage category

3

Degree of protection (IP)

IP20

Number of protected poles

1

Concurrently switching neutral conductor

Width in number of modular spacings

2

Suitable for flush-mounted installation

Pollution degree

2

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

With interlocking device

Frequency

50 Hz

Disconnection characteristic

Short-time delayed

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity according to EN 61009

6kA

Connectable conductor cross section solid-core

1 .. 25mm²

Rated current

40A

Rated fault current

0.03A

Leakage current type

A

Number of poles (total)

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.