Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Degree of protection (IP)IP20
Rated insulation voltage Ui500V
Built-in depth75.5mm
Rated voltage240V
Number of protected poles1
Pollution degree2
Current limiting class3
Width in number of modular spacings2
Release characteristicC
Over voltage category3
Surge current capacity0.25kA
Frequency50 Hz
Connectable conductor cross section solid-core1 - 25mm²
Flush-mounted installationNo
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to IEC 60947-20kA
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section multi-wired1 - 25mm²
With interlocking deviceNo
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610096kA
Anti-nuisance tripping versionNo
Rated current10A
Rated fault current0.01A
Leakage current typeAC
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-C10/1N/001

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Degree of protection (IP)

IP20

Rated insulation voltage Ui

500V

Built-in depth

75.5mm

Rated voltage

240V

Number of protected poles

1

Pollution degree

2

Current limiting class

3

Width in number of modular spacings

2

Release characteristic

C

Over voltage category

3

Surge current capacity

0.25kA

Frequency

50 Hz

Connectable conductor cross section solid-core

1 .. 25mm²

Flush-mounted installation

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section multi-wired

1 .. 25mm²

With interlocking device

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

6kA

Anti-nuisance tripping version

Rated current

10A

Rated fault current

0.01A

Leakage current type

AC

Number of poles (total)

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.