Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Leakage current typeAC
Rated current13A
Voltage typeAC
Release characteristicC
Rated fault current0.01A
Rated voltage240V
Built-in depth75.5mm
Rated insulation voltage Ui500V
Frequency50 Hz
Over voltage category3
Degree of protection (IP)IP20
Number of protected poles1
Width in number of modular spacings2
Current limiting class3
Pollution degree2
Surge current capacity0.25kA
Number of poles (total)2
With interlocking deviceNo
Rated short-circuit breaking capacity according to IEC 60947-20kA
Connectable conductor cross section multi-wired1 - 25mm²
Flush-mounted installationNo
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-25 - 40°C
Disconnection characteristicUndelayed
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610096kA
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-C13/1N/001

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Leakage current type

AC

Rated current

13A

Voltage type

AC

Release characteristic

C

Rated fault current

0.01A

Rated voltage

240V

Built-in depth

75.5mm

Rated insulation voltage Ui

500V

Frequency

50 Hz

Over voltage category

3

Degree of protection (IP)

IP20

Number of protected poles

1

Width in number of modular spacings

2

Current limiting class

3

Pollution degree

2

Surge current capacity

0.25kA

Number of poles (total)

2

With interlocking device

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Flush-mounted installation

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 40°C

Disconnection characteristic

Undelayed

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

6kA

Anti-nuisance tripping version

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.