Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Rated voltage240V
Rated current13A
Release characteristicC
Rated insulation voltage Ui500V
Leakage current typeA
Rated fault current0.03A
Built-in depth75.5mm
Surge current capacity0.25kA
Pollution degree2
Over voltage category3
Width in number of modular spacings2
Current limiting class3
Degree of protection (IP)IP20
Frequency50 Hz
With interlocking deviceNo
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity according to IEC 60947-20kA
Connectable conductor cross section solid-core1 - 25mm²
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Number of protected poles2
Ambient temperature during operating-25 - 40°C
Number of poles (total)2
Anti-nuisance tripping versionNo
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-C13/2/003-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Rated voltage

240V

Rated current

13A

Release characteristic

C

Rated insulation voltage Ui

500V

Leakage current type

A

Rated fault current

0.03A

Built-in depth

75.5mm

Surge current capacity

0.25kA

Pollution degree

2

Over voltage category

3

Width in number of modular spacings

2

Current limiting class

3

Degree of protection (IP)

IP20

Frequency

50 Hz

With interlocking device

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Connectable conductor cross section solid-core

1 .. 25mm²

Concurrently switching neutral conductor

Flush-mounted installation

Number of protected poles

2

Ambient temperature during operating

-25 .. 40°C

Number of poles (total)

2

Anti-nuisance tripping version

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.