Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated voltage240V
Rated current16A
Built-in depth75.5mm
Voltage typeAC
Release characteristicC
Rated insulation voltage Ui500V
Number of poles (total)2
Degree of protection (IP)IP20
Flush-mounted installationNo
Leakage current typeAC
Rated impulse withstand voltage Uimp4kV
Number of protected poles1
Pollution degree2
Surge current capacity0.25kA
Frequency50 Hz
Rated short-circuit breaking capacity according to IEC 60947-20kA
Width in number of modular spacings2
Connectable conductor cross section solid-core1 - 25mm²
With interlocking deviceNo
Ambient temperature during operating-25 - 40°C
Current limiting class3
Concurrently switching neutral conductorYes
Anti-nuisance tripping versionNo
Over voltage category3
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated fault current0.03A
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicUndelayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FRBm6-C16/1N/003

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

240V

Rated current

16A

Built-in depth

75.5mm

Voltage type

AC

Release characteristic

C

Rated insulation voltage Ui

500V

Number of poles (total)

2

Degree of protection (IP)

IP20

Flush-mounted installation

Leakage current type

AC

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

1

Pollution degree

2

Surge current capacity

0.25kA

Frequency

50 Hz

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Width in number of modular spacings

2

Connectable conductor cross section solid-core

1 .. 25mm²

With interlocking device

Ambient temperature during operating

-25 .. 40°C

Current limiting class

3

Concurrently switching neutral conductor

Anti-nuisance tripping version

Over voltage category

3

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated fault current

0.03A

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.